IgE, Serum (IGE) |
EPIC Test Name
IGEEPIC Code
LAB74Specimen Requirements
plasma | |
---|---|
Minimum Volume: | 0.5 mL |
Collection: | Collect specimens using standard laboratory procedures. |
Transport: | Room Temperature ASAP |
Stability: | Refrigerated: 7 days at 2-8 degrees C Frozen: 6 months at -15 to -25 degrees C |
Container: | LT GRN |
Rejection Causes: | Hemolysis, lipemic, Insufficient Sample Volume |
Methods
ImmunoassayTurnaround Time
Specimen | Frequency |
---|---|
plasma | Tuesday and Fridays |
Reference Ranges
Immunoassay
Age | All Range | Unit |
---|---|---|
0 day up to 1 month | <2 IU/mL | IU/mL |
1 month up to 1 year | <15 IU/mL | |
1 year up to 6 years | <60 IU/mL | |
6 years up to 10 years | <90 IU/mL | |
10 years up to 15 years | <200 IU/mL | |
15 years up to 999 years | <100 IU/mL |
Performed
Lab |
---|
Chemistry - Community |